Inspection Status Information
Your search returned 25 result(s).
Project No.: RGB51606
Description: RES/ROOM ADDITION
Address: 15618 BEAR CREEK DR
City: TPA 33624
Parcel: 016351.0018
Permit Issue Date: 11/26/2019
Permit Status: CONVERTD
Date | Inspection Item | Description | Inspector / Initial | Action | Notation |
---|---|---|---|---|---|
02/20/2020 | 102 | Footing Forms / Wall Footer | PRYORR / PRYORR | AP | |
03/24/2020 | 105 | Slab | NICKG / NICKG | AP | |
04/09/2020 | 110 | Bond Beam or Lintel | ferryr / FERRYR | CO | FBC 106.4 Not built to plans Missing dowel in cell from footing according to plans. Marked on plans of missing dowel |
04/10/2020 | 110 | Bond Beam or Lintel | NICKG / NICKG | AP | |
05/21/2020 | 115 | Roof Sheathing | PRYORR / PRYORR | AP | |
05/21/2020 | 117 | Wall Sheathing | PRYORR / PRYORR | AP | Gable. Ok to tyvek |
08/06/2020 | 120 | Framing | ferryr / FERRYR | AP | |
08/14/2020 | 160 | Insulation | ferryr / FERRYR | AP | |
05/29/2020 | 198 | Roof Final | SZWEJKOWSKIJ / SZWEJKOWSKIJ | AP | |
11/04/2020 | 199 | Building Final | ferryr / FERRYR | AP | |
06/18/2020 | 250 | Electrical Rough-In | TAPPJ / TAPPJ | AP | |
10/07/2020 | 299 | Electrical Final | WILLIAMS / WILLIAMS | AP | |
06/30/2020 | 350 | Mechanical Rough-In/HVAC | BUHLERS / BUHLERS | CO | QUESTIONS CONTACT STEVE BUHLER (813)521-1835 HCC 8-1 PART A 110.1- LOCK OUT- 210 PM- LEFT NOTE |
07/08/2020 | 350 | Mechanical Rough-In/HVAC | JONESML / JONESML | CO | QUESTIONS: MIKE JONES 813-404-6802 MC305.5 - Piping must be protected from physical damage. ADD NAIL PLATES AT TOP PLATE ON DRYER PIPING AND ON WALL STUDS PVC DRAIN PASSES THROUGH. HCC 8-1 PART A (107.3.1) DOCUMENTS REQUIRED ON SITE. POST ENERGY CALCS AND LOAD CALCS FOR REVIEW. |
07/10/2020 | 350 | Mechanical Rough-In/HVAC | JONESML / JONESML | CO | QUESTIONS: MIKE JONES 813-404-6802 MC305.5 - Piping must be protected from physical damage. ADD NAIL PLATES AT TOP PLATE ON DRYER PIPING AND ON WALL STUDS PVC DRAIN PASSES THROUGH. HCC 8-1 PART A (107.3.1) DOCUMENTS REQUIRED ON SITE. POST ENERGY CALCS AND LOAD CALCS FOR REVIEW. |
07/28/2020 | 350 | Mechanical Rough-In/HVAC | BUHLERS / BUHLERS | AP | |
10/02/2020 | 399 | Mechanical Final/HVAC | SCHULERF / SCHULERF | RT | FRED SCHULER 813-335-7308 MC301.15 - Outdoor equipment improperly anchored/not anchored. MISSING HURRICANE CLIPS MC304.12 - Area served. Labeling of equipment. LABEL ALL EQUIPMENT WITH PERMANENT UNIT #'S MC306.1.1 - Clearances for equipment in alcove/compartment. A/H BLOCKED BY FRAMING, MOVE A/H AWAY FROM WALL MINIMUM 4" FROM WALL FOR SEALING. MC307.2.4 - Drain traps. Condensate drain shall be trapped as required by the manufacturer MC601.6 - Provide balanced air. Return air openings FOR BEDROOM. M601.5 FREE DRAW RETURN CAN NOT PULL FROM LAUNDRY CLOSET, MUST DUCT RETURN TO BEDROOM |
10/27/2020 | 399 | Mechanical Final/HVAC | JOSHID / JOSHID | AP | |
03/16/2020 | 400 | Sewer/Sewer Tie In | 9988 / 9988 | CA | IVRS - RI canceled |
04/24/2020 | 400 | Sewer/Sewer Tie In | JIMENEZD / JIMENEZD | AP | |
07/29/2020 | 445 | Tubset/2nd Plumbing Rough In | JIMENEZD / JIMENEZD | RT | FPC 303.4/P2609 - Fixture and or material not approved for use. NEED HARDCAP ON WASHING MACHINE AREA. FPC 305.6 - Nail plates missing, not an approved type and or not installed per code. WAHING MACHINE AREA. FPC 308/P2605 - Piping not supported per code. MID STORY STRAPS. FPC 312.5 - Water supply system test failed. LEAK @ DRY FIT ON SHOWER VALVE. P2709.4 - Shower drain flange not installed flush with sub base. SHALL NOT HAVE A BUMP AROUND DRAIN. FPC 417.5.2 / P2709.2 - Shower lining not installed per code. NEED TO PROTECT CURB CORNERS. |
07/30/2020 | 445 | Tubset/2nd Plumbing Rough In | JIMENEZD / JIMENEZD | RR | FPC 308/P2605 - Piping not supported per code FPC 312.9 - Shower liner test failed |
08/05/2020 | 445 | Tubset/2nd Plumbing Rough In | JIMENEZD / JIMENEZD | AP | |
03/16/2020 | 450 | Plumbing Rough-In / Main Drain | GONZALEZP / GONZALEP | AP | |
10/02/2020 | 499 | Plumbing Final | JIMENEZD / JIMENEZD | AP |