Locks, Holds, Notices, or Comments
Your search returned 4 result(s).
Project No.: RGB55434
Description: WBY/RES/SHED AND COVERED DECK
Address: 1028 CANAL ST
City: RKN 33570
Parcel: 031760.0000
Permit Issue Date:
Permit Status: CLOSED
L/H/N/C | Text | From | Through |
---|---|---|---|
Comment | INTAKE 08/29/2020 BY LJP FILE ROUTED TO BUILDING PLANS EXAMINER FOR REVIEW OF PLANS AND SITE PLAN REVIEW OF SETBACKS AND FLOOD VERIFICATION | 8/29/2020 | 12/31/2020 |
Comment | ZONING & FLOOD CONFORMANCE REVIEW has been denied by Holly Swanson for code compliance on 09/14/2020. Please resubmit with the following corrections clouded on the site plan: 1. The property is located in the VE flood zone. Please provide the base flood elevation (11' NAVD 1988) and proposed finish floor elevation on the drawing. 2. All structures located on the site must be shown (accurately) and labeled on the plan. This includes the other detached covered structure and dock in the rear yard. 3. All easements (as applicable) must also be shown and labeled on the plan. 4. All property line dimensions must also be shown on the plan. Questions may be directed to Holly Swanson at 813-274-6542 or swansonh@hcflgov.net. Permit file placed in the County Center denied room. Please visit the following link for step by step instructions for all digital submittals including document requirements, corrections, and revisions https://www.hillsboroughcounty.org/en/residents/public-safety/emergency-management/submit-your-development-services-application or email all digital documents to planreview@hillsboroughcounty.org. | 9/14/2020 | 12/31/2020 |
Comment | BUILDING PLAN REVIEW has been denied by Holly Swanson for code compliance on 09/14/2020. Please resubmit with the following corrections clouded on the drawings: 1. In addition to the Florida Building Code, all construction located in the VE zone (Coastal High Hazard Area) must comply with section 322.3 of the Florida Residential Building Code and Hillsborough County Construction Code section 301.2.5. in accordance with with ASCE/SEI 24-14 design requirements for Coastal High Hazard Areas. 2. Signed and sealed Soils, Foundation, Wave Run Up and Scour Analyses must be provided by a FL licensed engineer. 3. The engineer's plans and calculations must be electronically signed, sealed and third party verified. Pdf copies of hand signed & sealed drawings are not acceptable. Questions may be directed to Holly Swanson at 813-274-6542 or swansonh@hcflgov.net. Permit file placed in the County Center denied room. Please visit the following link for step by step instructions for all digital submittals including document requirements, corrections, and revisions https://www.hillsboroughcounty.org/en/residents/public-safety/emergency-management/submit-your-development-services-application or email all digital documents to planreview@hillsboroughcounty.org. | 9/14/2020 | 12/31/2020 |
Comment | ***APPLICANT MUST SUBMIT A SUBSTANTIAL IMPROVEMENT PACKAGE PRIOR TO RE-REVIEW*** | 9/14/2020 | 12/31/2020 |