Date | Inspection Item | Description | Inspector / Initial | Action | Notation |
---|---|---|---|---|---|
08/25/2020 | 102 | Footing Forms / Wall Footer | barrosol / BARROSOL | AP | |
09/14/2020 | 105 | Slab | barrosol / BARROSOL | AP | |
01/20/2021 | 107 | Stem Wall | barrosol / BARROSOL | AP | was ap 9/14/20 |
10/02/2020 | 110 | Bond Beam or Lintel | barrosol / BARROSOL | AP | tie in survey ap |
10/20/2020 | 115 | Roof Sheathing | LOUGHLINT / LOUGHLINT | AP | |
10/20/2020 | 117 | Wall Sheathing | LOUGHLINT / LOUGHLINT | AP | |
12/09/2020 | 120 | Framing | LOUGHLINT / LOUGHLINT | AP | Per contract inspector Ezz Elgayar |
12/14/2020 | 122 | Pre-Siding House Dry-In | hanchettr / HANCHETR | AP | hardie wrap |
12/15/2020 | 160 | Insulation | SPAAKE / SPAAKE | AP | |
09/11/2020 | 200 | Underground Electrical | scottk / SCOTTK | AP | |
08/25/2020 | 205 | Ufer Ground | BLawson / LAWSONB | AP | |
03/02/2021 | 240 | Temp Power | TAPPJ / TAPPJ | AP | RTT |
12/02/2020 | 250 | Electrical Rough-In | hendriksenk / HENDRIKSENK | AP | |
12/02/2020 | 257 | Low Voltage Rough-in | hendriksenk / HENDRIKSENK | AP | |
03/02/2021 | 297 | Low Voltage Final | TAPPJ / TAPPJ | AP | |
03/02/2021 | 299 | Electrical Final | TAPPJ / TAPPJ | CA | On Site |
11/24/2020 | 350 | Mechanical Rough-In/HVAC | MESADA / MESADA | CO | QUESTIONS CALL DARIO 520-9632 MC307.2.2 - PLASTIC TUBING NOT ALLOWED IN ATTIC MUST BE HARD PIPE. COMING FROM MINI SPLIT IN BONUS ROOM |
12/02/2020 | 350 | Mechanical Rough-In/HVAC | MESADA / MESADA | AP | |
02/26/2021 | 399 | Mechanical Final/HVAC | JOSHID / JOSHID | AP | |
02/22/2021 | 400 | Sewer/Sewer Tie In | LIVELYD / LIVELYD | AP | |
02/15/2021 | 430 | Water Service | HENDERSONR / HENDERSONR | AP | |
11/09/2020 | 445 | Tubset/2nd Plumbing Rough In | LIVELYD / LIVELYD | AP | |
09/11/2020 | 450 | Plumbing Rough-In / Main Drain | WESTA / WESTA | AP | Andrew West, contract inspector for JPI. |
02/25/2021 | 499 | Plumbing Final | LIVELYD / LIVELYD | AP | |
03/02/2021 | 21111 | FAX TECO (FOR OFFICE USE ONLY) | TAPPJ / TAPPJ | TE | |
03/02/2021 | 21111 | FAX TECO (FOR OFFICE USE ONLY) | 9988 / 9988 | FAX | IVRS - Inspection :* |