Date | Inspection Item | Description | Inspector / Initial | Action | Notation |
---|---|---|---|---|---|
06/09/2017 | 103 | Monolithic Slab | Brooksro / BROOKSRO | CA | |
06/12/2017 | 103 | Monolithic Slab | Brooksro / BROOKSRO | AP | |
07/05/2017 | 108 | Tie-in Survey | dtw / WATSOND | AP | |
06/22/2017 | 110 | Bond Beam or Lintel | dietzh / DIETZH | AP | |
07/25/2017 | 115 | Roof Sheathing | BROOKSRO / BROOKSRO | AP | |
07/25/2017 | 115 | Roof Sheathing | BROOKSRO / BROOKSRO | AP | |
07/25/2017 | 117 | Wall Sheathing | BROOKSRO / BROOKSRO | AP | |
10/16/2017 | 120 | Framing | BLANCOH / BLANCOH | CO | FBC 2304.9.6/FBC 1609.1.3 - Clips, ties, hold downs, or straps not installed to manufacturer's specifications/ missing clips along base of stairwell wall |
10/18/2017 | 120 | Framing | BLANCOH / BLANCOH | AP | |
10/18/2017 | 122 | Pre-Siding House Dry-In | SPAAKE / SPAAKE | CO | R703.6.2 - Metal lath installation not in compliance w/ application requirements of ASTM C 1063 See CO tag for SFT12190 |
10/26/2017 | 122 | Pre-Siding House Dry-In | BROOKSRO / BROOKSRO | NR | |
10/31/2017 | 122 | Pre-Siding House Dry-In | BLANCOH / BLANCOH | AP | |
10/16/2017 | 123 | Fire Rated Assembly | BLANCOH / BLANCOH | AP | |
10/20/2017 | 160 | Insulation | BROOKS / BROOKSRO | NR | R602.1.2(1-6)/ FBC 717.2.2 - Penetrations not sealed.Following code violtatons as well,R602.1.2 , FBC109.3.3 Insulate be hind tub,attic acess no batts or built up . Entire wall common to other units is not fire block at top. Arch in first floor not blocked,Storage area not sealed |
10/24/2017 | 160 | Insulation | BROOKSRO / BROOKSRO | CO | R302.11/FBC 717.3 - Draft stop required. Prior corrections not complete |
10/26/2017 | 160 | Insulation | BROOKSRO / BROOKSRO | CO | R602.1.2(1-6)/ FBC 717.2.2 - Penetrations not sealed |
10/27/2017 | 160 | Insulation | BROOKSRO / BROOKSRO | AP | |
11/28/2017 | 198 | Roof Final | BLANCOH / BLANCOH | AP | |
12/19/2017 | 199 | Building Final | mcdougalm / MCDOUGALM | CO | FBC 105.11 - Final termite required/ handrail must be installed |
12/21/2017 | 199 | Building Final | GILBERTJ / GILBERTJ | AP | |
06/05/2017 | 200 | Underground Electrical | RobertsLe / ROBERTSLE | AP | |
06/12/2017 | 205 | Ufer Ground | RobertsLe / ROBERTSLE | AP | |
12/04/2017 | 240 | Temp Power | gerdes / GERDESG | AP | |
08/09/2017 | 250 | Electrical Rough-In | gerdes / GERDESG | AP | |
08/10/2017 | 257 | Low Voltage Rough-in | CrockettK / CROCKETTK | AP | |
12/08/2017 | 297 | Low Voltage Final | gerdes / GERDESG | AP | |
08/09/2017 | 299 | Electrical Final | gerdes / GERDESG | COM | 2 GR Rods - Check feeders on Final |
12/12/2017 | 299 | Electrical Final | RobertsLe / ROBERTSLE | CO | HCCC 13-31 (110.5) Work not ready for inspection. NM hanging out of wall at AC, Missing several breakers in panel, Closet light Clearance. 100 % reinspection required. |
12/18/2017 | 299 | Electrical Final | gerdes / GERDESG | NR | HCCC 13-31 (110.5) Work not ready for inspection |
12/19/2017 | 299 | Electrical Final | gerdes / GERDESG | AP | |
08/03/2017 | 350 | Mechanical Rough-In/HVAC | LEYTZEM / LEYTZEM | AP | |
12/01/2017 | 399 | Mechanical Final/HVAC | LEYTZEM / LEYTZEM | AP | |
08/15/2017 | 400 | Sewer/Sewer Tie In | LITTLETOND / LITTLETOND | AP | |
08/15/2017 | 430 | Water Service | LITTLETOND / LITTLETOND | AP | |
09/26/2017 | 445 | Tubset/2nd Plumbing Rough In | HERNANDEZAN / HERNANDEZAN | AP | |
06/07/2017 | 450 | Plumbing Rough-In / Main Drain | LAZUKINA / LAZUKINA | AP | |
12/18/2017 | 499 | Plumbing Final | LITTLETOND / LITTLETOND | AP | |
12/08/2017 | 900 | Engineering & Zoning | RD / ZIMMERMANG | AP | |
12/08/2017 | 910 | Commercial Landscape | SME / EYSTERS | RO | |
12/11/2017 | 910 | Commercial Landscape | BEAVERSJ / BEAVERSJ | AP | IVRS - Inspection :* |
12/20/2017 | 21111 | FAX TECO (FOR OFFICE USE ONLY) | 9988 / 9988 | FAX | IVRS - Inspection :* |
12/20/2017 | 21111 | FAX TECO (FOR OFFICE USE ONLY) | MAV / VAZQUEZM | TE | |
12/22/2017 | 21115 | FAX CO (FOR OFFICE USE ONLY) | ld / DODSONL | AP |